General Specifications
Spec: Description:
Dimensions Nominal 205 mm (W) x 640 mm (H) (8.07 in (W) x 25.19 in (H))
Materials Transducers: Valox 357 U and syntactic foam face
Bracket: 304 stainless steel
Cable Length Standard: 5 m, 10 m, 20 m, or 30 m (16.4 ft, 32.8 ft, 65.6 ft, or 98.4 ft).
Optional: up to 150 m (492 ft) maximum; increments of 10 m (32.8 ft) only
Maximum Separation 500 m (1640 ft)
Mounting Connection BSP or 1 in NPT
Enclosure Protection IP68 / NEMA 6P
Operating Temperature (Electronics) -40 °C to +90 °C (-40 °F to +194 °F)
Measurement Range 0.3 m - 2 m (0.98 ft - 6.56 ft) from the face of the lower transducer; 1.5 m (5 ft) max. for MCERTS certification
Frequency 125 kHz
Beam Angle <10°
Controller Compatibility FlowCERT only
Onaylar
MCERTs Class 1 - 0.044% accuracy when combined with the FlowCERT Controller
CE Approval: 2014/30/EU - EMC & 2014/34/EU ATEX Directives
CE Standards applied: Standards applied: EN 60079-0:2012+A11:2013 / EN 60079-11:2012 / EN 60079-18:2009 / EN 60079-26:2007 / EN 61326-1:2013
ATEX Approval: ATEX EEx m II T6 standard.
FM/FMc Approval Available