SandAlert Portatif

Monday, September 19, 2022

Akustik Kendinden güvenli akış anahtarı
Kelepçeli Sensör
Kendinden güvenli
Isensys SandAlert Monitor ile kullanın

İSensys SandAlert Portable, bir sensör, montaj kayışı ve 50 m (164 ft) uzatma kablosu içeren eksiksiz bir taşınabilir kum izleme sistemidir. SandAlert Portable, taşınmasını ve sabitlenmesini kolaylaştıran sağlam bir pelikan çantasına Sabitlenmiştir. A SandAlert Monitor provides a graphics display that gives real-time sand data and trend information for up to 90 days at 1-minute intervals. A PC interface is also available and allows data to be downloaded and graphical analysis to be conducted. The iSensys SandAlert Portable is perfect for short-term well evaluation and to determine methods of control.

Oil and gas well operators know how important it is to maintain production at optimum levels, and an important part of that optimization is a clear and accurate measurement of solids production. The iSensys SandAlert range provides robust, dependable measurement of solids within the production stream so plant operators can be confident they are operating as efficiently as possible.
The SandAlert Monitor consists of two parts, The PulsarGuard 2001 sensor, a small robust clamp-on acoustic monitor, and the SandAlert controller. SandAlert is ideal wherever you need to keep wells producing efficiently at the highest rate possible; whenever you need a quantitative, real-time, and accurate measurement of produced solids/sand particles.
For years, the market has demanded the capability of measuring particles without needing flow data. The unique PulsarGuard sensor is installed after a suitable pipe bend where the turbulent flow profile is fully developed. The sensor measures solids production directly, without the need for an external or additional flow measurement.
General Specifications
Spec:                                                                 Description:
Cable Entry Detail                                                      SandAlert Monitor: 6 cable gland knockouts on the base (4 x PG11, 1 x PG9, 1 x PG13.5) and 5 on the rear (5 x PG11)
PulsarGuard 2001 Sensor: 1 x M20 Brass (fitted with EMC gland)
Relays                                                                  3 Form “C” SPDT rated at 5 A at 240 V. Trip point from 0-100% of range
Extension Cable                                                    50 m (164 ft)
Operating Temperature (Electronics)            -20 °C to +60°C (-4 °F to +140 °F)
Operating Temperature (Sensor)                         -20 °C to +80°C (-4 °F to +176 °F)
IP Rating                                                                  IP65 with lid closed, IP50 with lid open
CE Approval                                                                  Sensor: EMC Approval to BS EN 50081-1:1992 for emissions, BS EN 50082-2: 1995 for immunity, BS EN 61010-11993 for low voltage directive
Hazardous Area                                                     Sensor: ATEX II 1 G EEx is IIC T4 (Tamb= -20 °C to 80 °C). Certificate No. Sira 04ATEX2110
Analog Outputs                                                     4-20mA/0-20mA into 500 ohms (user programmable and adjustable) 0.1% resolution
Digital Outputs                                                     RS232 via RJ11 port
Communications                                                     RS485 Modbus protocol
Power Supply                                                     90-260 V AC or 24 V DC. Power consumption 20 W maximum
Dimensions                                                                  406 mm x 330 mm x 174 mm (15.98 in x 12.99 in x 6.85 in)
Options
Option:                                                          Description:
PC Interface                                                                 Allows data to be downloaded and graphical analysis to be conducted
Cases                                                                  Battery Case: providing 24 V DC
                                                                                          Toolkit Case: providing all the tools necessary for installing the SandAlert Portable in remote locations

Sensor

CE, EMC Approval to BS EN 50081-1:1992 for emissions, BS EN 50082-2: 1995 for immunity, BS EN 61010-11993 for low voltage directive
ATEX II 1 G EEx is IIC T4 (Tamb= -20 °C to 80 °C). Certificate No. Sira 04ATEX2110